|
DKK-TOA WQC-22A
|
|
Easy measurement of 6 items (pH, temp., DO, conductivity, turbidity, salinity)
Ideal for applications such as rivers, lakes, dams, etc.
Easy maintenance with cartridge electrode
Measurements at depth of 30m is achievable with specific electrodes
AC/DC 2-way power supply
|
Water Quality Checker
|
|
|
DKK002-WQC-24 Multiparameter Water Quality Meter (8~11 parameters plus water depth available)
|
|
Application
>Multiparameter Meter
> 35 Days Data Storage
> Up To 11 Simultaneous Parameters > Up To 100m Depth > GPS Interface > Measure Turbidity, pH, DO and MorePROMOTION NOW!
|
Water
|
|
|
DO-5519 DISSOLVED OXYGEN METER, two displays
|
|
* Range : 0 to 20 mg/L x 0.1 mg/L.
* Temperature : 0 to 50 oC.
* LCD display, pocket size.
* Automatic temperature compensation.
* 1600 Data logger point.
* Optional data transmition software, SW-DL2005.
* Separate probe, easy operation.
* RS-232 interface, Record (max., min.)
* Power : DC 9V battery or DC 9V adapter in.
|
Water
|
|
|
DO-5512SDAA SD Card real time dissolved oxygen data recorder
|
|
* Real time data recorder, save the data into the SD memory card and can be download to the
Excel, extra software is no need.
* Dissolved oxygen range : 0 to 20 mg/L.
* Auto temp. compensation, Auto Calibration.
* % salt and height value compensation adj..
* The polarographic type oxygen probe with an incorporated temperature sensor.
* Probe head with diaphragm set and electrolyte are included.
* Record (Max., Min.), Data hold, zero adjust.
* RS232/USB computer... |
Water
|
|
|
DKK0032-OZ-21Pv2 OZONE TESTER (DISSOLVED OZONE METERS)
|
|
Simple, reagentless measurement of concentration of ozone stream water produced by ozone water generatorWaterproof design (IP67: 1m depth, up to 30mins)Polishing beads cleaning method allows for stable measurementExternal printer connectable |
Water
|
|
|
DKK0056-SSM-21P HANDHELD SURFACE SALINITY METER
|
|
Compliant with PSPC
Ideal for surface salinity measurements of paints used in ship coatings
Simple operation (just attach the cell to the meter and inject pure water into the cell)
Measurement range
0~199.9mg/m2, 0~1999mg/m20~199.9μS/cm, 0~1.999mS/cm0~50℃ |
Water
|
|
|
DKK-TOA DVP-03
|
|
Designed for oil refinery
Measures vapor pressure of petroleum products like gasoline
Vapor pressure is measured by measuring static pressure of the sample that is jetting out from the nozzle at the constant temperature
Measurement result attained via Reid method for vapor pressure
Meas. range
0.01 - 1 MPa abs 0 - 0.15 MPa abs
|
Vapor Pressure Analyzer
|
|
|
DKK-TOA TUF-1600
|
|
Suitable for water purification process (including river water, etc.)
Surface scattering light method employed; 1 range/2 ranges/3 ranges available
Reduces flow volume of sample water to 1/2 of existing models
RS-485 equipped as standard specification; compatible with Modbus communication system
Freely mountable on walls, racks, etc. for the compact lightweight design
Meas. range
0 - 2 to 0 - 2000 (1 - 3 ranges) (mg/L, ppm, FTU, NTU)
|
Turbidity Analyzer
|
|
|
DKK-TOA TUH-1600
|
|
High Sensitivity Turbidity Analyzer TUH-1600
Highly-sensitive turbidity analyzer suitable for water purification process
Surface scattering light method employed; 1 range/2 ranges/3 ranges available
RS-485 equipped as standard specification; compatible with Modbus communication system
Freely mountable on walls, racks, etc. for the compact lightweight design
Meas. range
0 - 0.2 to 0 - 2.0 (1 - 3 ranges) (NTU)
|
Turbidity Analyzer
|
|
|
DKK-TOA TUI-100
|
|
Turbidity Meter with Integrating Sphere TUI-100
Integrating sphere system employed for lab turbidity measurements
Continuous measurement of turbidity in tap water, river water, industrial water, etc.
Accurate results for minimized influence of color
Meas. range
0 - 0.5/5 to 0 - 100/1000 Cell length: 50mm or 10mm (selectable) (mg/L, ppm, FTU, NTU)
|
Turbidity Analyzer
|
|
|
DKK-TOA COL-110
|
|
Colorimeter/Turbidity Meter COL-110
Color and turbidity can be measured simultaneously by dual wavelength with just one meter
Equipped with interactive easy-to-use colortouch panel
Meas. range
Color: 0 - 10/20/30 (degrees C, DEG) Turbidity: 0 - 2/4/5/10 (degrees C, mg/L, ppm)
|
Turbidity Analyzer
|
|
|
DKK-TOA HDM-135A(2-wire)/HDM-136A(4-wire)
|
|
Industrial pH Transmitter HDM-135A(2-wire)/HDM-136A(4-wire)
Easy-to-use pH analyzer for field installation in a compact and rigid aluminum enclosure
Easier calibration done with standard solution
Auto determination of electrode deterioration
Alterable output range
Automated self-diagnosis of fault (burn-out output)
Meas. range
-1 - 14
|
Transmitter for Industrial pH/ORP Analyzer
|
|
|
DKK-TOA HDM-137A(2-wire)/HDM-138A(4-wire)
|
|
Industrial ORP Transmitter HDM-137A(2-wire)/HDM-138A(4-wire)
Easy-to-use ORP analyzer for field installation in a compact and rigid aluminum enclosure
Automatic check done with standard solution
Auto-detection of electrode deterioration
Alterable output range
Automated self-diagnosis of fault (burn-out output)
Meas. range
-2000 - +2000mV
|
Transmitter for Industrial pH/ORP Analyzer
|
|
|
DKK-TOA HBM-165H(2-wire)
|
|
pH / ORP Transmitter with HART Interface HBM-165H(2-wire)
HART communication protocol interface with a 2-wire, 24 VDC circuit
Available for both pH and ORP measurements
Diecast aluminum enclosure, digital display and a wide range of other useful features
One-touch auto calibration
Self-diagnostic function
Meas. range
-1.00 - 15.00 ORP -2000 - 2000 mV
|
Transmitter for Industrial pH/ORP Analyzer
|
|
|
DKK-TOA HBM-160/HBM-162(4-wire)
|
|
Industrial pH/ORP Transmitter HBM-160/HBM-162(4-wire)
Multi-function pH/ORP analyzer for field installation in a compact aluminum diecast enclosure
One-touch calibration and various self-diagnostic functions
2-point contact signal and 2-channel output including temperature (RS-232 optional)
Power supply: AC90~264V, 50/60Hz
Meas. range
pH meter (HBM-160) : pH -1 - 15 ORP meter (HBM-162) : ORP -2000 - +2000mV
|
Transmitter for Industrial pH/ORP Analyzer
|
|
|
DKK-TOA HC-G70 (KCl Replenish-Free/Refillable) / HC-G72 (KCl Refillable)
|
|
Immersion Type Holder for Replaceable Tip Electrode HC-G70 (KCl Replenish-Free/Refillable) / HC-G72 (KCl Refillable)
HC-G70: Transparent PVC holder (heat resistance: 60 degrees C) and semi-transparent PP holder (heat resistance: 80 degrees C) available
HC-G72: SUS316 holder (heat resistance: 80 degrees C)
Length: 0.5 - 3.0m
KCl refillable type stores KCl inside the holder
Mounting bracket/flange available
|
Transmitter for Industrial pH/ORP Analyzer
|
|
|
DKK-TOA HC-G95 (KCl Replenish-Free)
|
|
Drop-In Type Detector for Replaceable Tip Electrode HC-G95 (KCl Replenish-Free)
Two selections: throw-in type for deep tanks or drop-in type with a protection pipe
Made from transparent PVC (heat resistance: 60 degrees C)
SUS protection pipe (maximum length: 5 m) and mounting bracket available
|
Transmitter for Industrial pH/ORP Analyzer
|
|
|
DKK-TOA HC-G80 (KCl Replenish-Free/Refillable) / HC-G82 (KCl Replenish-Free/Refillable)
|
|
Flow-Through Type Holder for Replaceable Tip Electrodes HC-G80 (KCl Replenish-Free/Refillable) / HC-G82 (KCl Replenish-Free/Refillable)
HC-G80: Transparent holders made of PVC (heat resistance: 60 degrees C) ; maximum pressure resistance: 0.15MPa
HC-G82: PP/SUS316 part (heat resistance: 80 degrees C) and PVDF/SUS316 part (heat resistance: 100 degrees C) ; maximum pressure resistance: 0.3 MPa
|
Transmitter for Industrial pH/ORP Analyzer
|
|
|
DKK-TOA PHC-7D
|
|
Immersion Type Sensor with Pulse Air Jet Cleaner PHC-7D
Immersion type pH/ORP electrode holder combined with pulse air jet cleaner
Cleaning by high-speed water stream created by the rapid expansion of pulse-jetted compressed air in the sample water
High cleaning effect due to air bubbles present in the water stream randomly hitting the electrode
No consumables required, such as reagents, brushes
|
Transmitter for Industrial pH/ORP Analyzer
|
|
|
DKK-TOA ODM-100A (2-wire) / ODM-110A (4-wire)
|
|
Industrial Low-Concentration DO Transmitter ODM-100A (2-wire) / ODM-110A (4-wire)
Easy-to-use low-concentration DO analyzer for field installation in a compact and rigid aluminum case
Simplified calibration procedure; auto detection of electrode deterioration
Alterable output range
Automated self-diagnosis of fault (burn-out output)
Meas. range
Minimum: 0 - 20 μg/L Maximum: 0 - 2000 μg/L
|
Transmitter for Industrial Low-Concentration DO Analyzer
|
|