YOKOGAWA DIFFERENTIAL PROBE 150 MHZ/1400 V 701927
|
|
The 701927 is a 50:1 or 500:1 high voltage (1400V peak) probe with extended bandwidth covering DC to 150MHz, This probe provides a balanced differential input, to be used with oscilloscopes with single-ended inputs (1 MΩ Input Impedance). This probe works with DLM2000, DLM4000, DL6000, DLM6000, DL9000 and SB5000. This probe is conveniently powered by the Yokogawa Probe Interface I/F. |
VOLTAGE PROBES
|
|
|
YOKOGAWA DIFFERENTIAL PROBE 100 MHZ/1400 V 700924
|
|
Frequency bandwidth: DC to 100 MHz
Maximum continuous input range: 1400 Volts
Attenuation Ratios: 100:1 or 1000:1
Functions with Digital Oscilloscopes, ScopeCorders or other waveform measuring instruments. |
VOLTAGE PROBES
|
|
|
YOKOGAWA DIFFERENTIAL PROBE 50 MHZ/7000 V 701926
|
|
Frequency bandwidth: DC to 50 MHz Maximum continuous voltage input: 7,000 Volts Attenuation ratios: 1000:1 or 100:1 Functions with Digital Oscilloscopes, ScopeCorders or other waveform measuring instruments. |
VOLTAGE PROBES
|
|
|
YOKOGAWA DIFFERENTIAL PROBE 15 MHZ/1000 V 700925
|
|
Frequency bandwidth: DC to 15 MHz Maximum continuous input range: 1000 Volts Attentuation Rations: 100:1 or 10:1 Functions with Digital Oscilloscopes, ScopeCorders and other waveform measuring instruments. |
VOLTAGE PROBES
|
|
|
YOKOGAWA 500 MHZ DIFFERENTIAL PROBE 701920
|
|
Differential Probe, 12Vp Differential, 30Vp Common-Mode, 500MHz, 10:1, 100kΩ w/ built-in LEMO lead pig-tail
Works with all scopes with BNC Input w/ 50Ω Input Termination. Requires 50Ω scope or use 700976 50Ω terminator. Requires /P2/P4 LEMO option or external probe power supply. |
VOLTAGE PROBES
|
|
|
YOKOGAWA 100 MHZ DIFFERENTIAL PROBE 701921
|
|
Bandwidth: DC to 100 MHz (-3 dB) |
VOLTAGE PROBES
|
|
|
YOKOGAWA 200 MHZ DIFFERENTIAL PROBE 701922
|
|
The 701922 is a 10:1 Differential Probe rated at 20Vpeak differential voltage input and 60Vpeak Common-Mode input with 200MHz bandwidth (-3dB). This probe is recommended for CAN bus and can be used with virtuallly any oscillscope with an internal 50Ω termination or use the external 50Ω 700976. This probe is powered via a built in pig-tail LEMO lead. This probe can be powered with Yokogawa scope option /P2 or /P4, or an external power supply 700938-3-D or 701934-D. The... |
VOLTAGE PROBES
|
|
|
YOKOGAWA 2.0 GHZ DIFFERENTIAL PROBE (PBD2000) 701923
|
|
PBD2000 Differential Probe, 5Vp Differential, 7Vp Common-Mode, 2GHz, 10:1, 50kΩ. Fits Yokogawa scope Probe Interface only: DLM2000, DL6000, DLM6000, DL9000, SB5000 |
VOLTAGE PROBES
|
|
|
YOKOGAWA 1.0 GHZ DIFFERENTIAL PROBE (PBDH1000) 701924
|
|
The PBDH1000 (701924) is a 25Vp Differential Probe powered by the Yokogawa Probe Interface. This probe can be used only with the Yokogawa DLM2000, DL6000, DLM6000, DL9000, and SB5000 series oscilloscope. |
VOLTAGE PROBES
|
|
|
YOKOGAWA 200 MHZ PASSIVE PROBE 701938
|
|
Passive Probe, 600Vp, 200MHz, 10:1, 10MΩ, 1.5mSupplied standard with DLM2000/DLM4000. |
VOLTAGE PROBES
|
|
|
YOKOGAWA 500 MHZ PASSIVE PROBE 701939
|
|
Passive Probe, 600Vp, 500MHz, 10:1, 10MΩ, 1.3mSupplied standard with DLM2000/DLM4000. |
VOLTAGE PROBES
|
|
|
YOKOGAWA MINIATURE PASSIVE PROBE 701946
|
|
Passive Probe, 400Vrms, 500MHz, 10:1, 10MΩ, 1.3m, 'Mini' w/ accy kit. Optional probe for DLM2000/DLM4000/DL6000/DLM6000/DL9000/SB6000 series.
Can also be ordered as a substitute for the standard probe when ordering DLM2000/DL6000/DLM6000. |
VOLTAGE PROBES
|
|
|
YOKOGAWA MINIATURE PASSIVE PROBE 701941
|
|
Passive Probe, 400Vrms, 500MHz, 10:1, 10MΩ, 1.2m, 'Mini'Typically used with DL1700 and DL7400 as an optional non-standard probe. |
VOLTAGE PROBES
|
|
|
YOKOGAWA MINIATURE PASSIVE PROBE 701942
|
|
Passive Probe, 400Vrms, 350MHz, 10:1, 10MΩ, 3.0m, 'Mini'For DL1600, DL1700E, and DL7400 series Optional probe for use with DL1600/DL1700/DL7400 series, see also 701941. |
VOLTAGE PROBES
|
|
|
YOKOGAWA 100:1 PROBE 701944
|
|
The 701944 is an oscilloscope passive probe supporting up to 1000Vrms, 400MHz bandwidth, and 100:1 attenuation ratio. The probe length is 1.2 meters, with a 50MΩ input resistance.
This probe is well suited for high voltage, higher bandwidth single ended voltage measurements at an affordable cost. It is compatible with Yokogawa oscilloscope models DLM2000, DLM4000, DL/DLM6000, DL9000, SB5000 and DL1700. See also 701945 for the 250MHz bandwidth version of this same probe. |
VOLTAGE PROBES
|
|
|
YOKOGAWA 100:1 PROBE 701945
|
|
Passive Probe, 1000Vrms, 250MHz, 100:1, 50MΩ, 3.0m, 'Mini' with extra-long 3m lead. Compatible with DL1700, DLM2000, DLM4000, DL/DLM6000, DL9000 and SB5000. See also 701944 for 400 MHz version of this same probe. |
VOLTAGE PROBES
|
|
|
YOKOGAWA 100:1 ISOLATED PROBE 701947
|
|
Passive Probe, 3540Vp-CAT I, 1000Vp-CAT II, 200MHz, 100:1, 100MΩ, 1.5m, 'Isolated Probe' 'Iso-Probe'. For use with 701250, 701251, 701260, 701280, 701281, 720210 isolated-input modules ONLY. For use with DL850 series, DL750/DL750P, SL1400, and SL1000. Not for use with CAT III or CAT IV measurements |
VOLTAGE PROBES
|
|
|
YOKOGAWA PBA1000 1.0 GHZ ACTIVE PROBE
|
|
Use this 10:1 active probe with the DL6054, DLM6054, DL9040/DL9040L , DL9505L/DL9705L, DLM2052/DLM2054 series to realize system measurements up to 500 MHz BW. |
VOLTAGE PROBES
|
|
|
YOKOGAWA PBA1500 (701914) 1.5 GHZ ACTIVE PROBE
|
|
Use this 10:1 active probe with the DL6104, DLM6104, DL9140/DL9140L , DL9510L/DL9710L, SB5000 series to realize system measurements up to 1.0 GHz BW. |
VOLTAGE PROBES
|
|
|
YOKOGAWA PBA2500 (701913) 2.5 GHZ ACTIVE PROBE
|
|
Use this 10:1 active probe with the DL6154, DL9240 series to realize system measurements up to 1.5 GHz BW. |
VOLTAGE PROBES
|
|