Measuring Range
|
Type
K : -190oC to 1333oC (-310oF
to 2431oF)
Type J : -190oC to 760oC (-310oF
to 1400oF)
|
|
Accuracy
|
(-190oC
to -0oC ) ( +/- 0.5% rdg + 0.7oC)
(-310oF to -0oF ) ( +/- 0.5% rdg +
1.4oF)
( 0oC to 1000oC) ( +/- 0.1% rdg +
0.5oC)
( 0oF to 1000oF) ( +/- 0.1% rdg +
1.0oF)
( 1000oC to 1333oC) ( +/- 0.2% rdg
+ 1oC)
( 1000oF to 2431oF) ( +/- 0.2% rdg
+ 2oF)
|
|
Resolution
|
-190oC
to 999oC (0.1oC)
1000oC to 1333oC ( 1oC)
-310oF to 999oF (0.1oF)
1000oF to 2431oF ( 1oF)
|
|
Input Protection
|
60VDC/24Vrms
|
|
Power Source
|
One
9V battery. 006p or NEDA1604 or IEC6F22
|
|
Battery Life
|
Approx.
50hr
|
|
Operating / Storage Condition
|
0oC
to 40oC (32oF to 104oF)below
80¢MRH.
-10oC to 60oC (14oF to
140oF) below 70¢MRH.
|
|
Dimensions
|
145(L)¡Ñ68(W)¡Ñ35(H)mm
|
|
Weight
|
Approx.
235g with battery
|
|
Accessories
|
Instruction
manual, Battery, Carry case, Software,
RS-232 cable, 9 Pin to 25 Pin gender changer.
|