PROVA CM-07
TRMS AC/DC CLAMP METER |
- High Resolution DC 10mA, AC 1mA
- True RMS
- Non-contact Current Frequency
Measuremen |
|
Range
|
Resolution
|
Accuracy
|
Remarks
|
|
DCA
0-40A
|
10mA
|
+/-
1.0% +/- 2dgts
|
|
|
DCA
0-150A
|
100mA
|
+/-
1.0% +/- 2dgts
|
|
|
DCA
150-200A
|
100mA
|
- 2.2% +/- 2dgts
|
|
|
DCA
200-400A
|
100mA
|
- 4.0% +/- 4dgts
|
|
|
ACA
0-4A
|
1mA
|
+/-
1.5% +/- 3dgts
|
True
RMS
|
|
ACA
0-40A
|
10mA
|
+/-
1.0% +/- 3dgts
|
True
RMS
|
|
ACA
0-150A
|
100mA
|
+/-
1.0% +/- 3dgts
|
True
RMS
|
|
ACA
150-200A
|
100mA
|
- 2.2% +/- 3dgts
|
True
RMS
|
|
ACA
200-400A
|
100mA
|
- 4.0% +/- 4dgts
|
True
RMS
|
|
Hz
0-1000KHz
|
0.1-100Hz
|
+/-
0.5% +/- 2dgts
|
0.1A
sensitivity Auto Range
|
|
Power Source: 2 X 1.5V AA UM3 Batteries
Current Consumption:
10mA
Operating Condition:
-10oC to 50oC at 85% max. RH
|
|
|
|
|
|
|