Ground Resistance (Auto range) :
Range Resolution Accuracy of Reading1,2
0.025 - 0.250 W 0.002 W ± 1.5% ± 0.02 W
0.250 - 1.000 W 0.02 W ± 1.5% ± 0.02 W
1.001 - 9.999 W 0.02 W ± 1.5% ± 0.1 W
10.00 - 50.00 W 0.04 W ± 1.5% ± 0.1 W
50.01 - 99.99 W 0.04 W ± 1.5% ± 0.5 W
100.0 - 200.0 W 0.4 W ± 3.0% ± 1.0 W
200.1 - 400.0 W 2 W ± 5.0% ± 5 W
400.1 - 600.0 W 5 W ± 10% ± 10 W
600.1 - 1500 W 20 W ± 20%
1Loop resistance non inductive , external field < 200
A/m, external electrical field < 1 V/m, conductor
centered.
2Resistance Measurement Frequency:
1.667KHz,3.333KHz(optional)
Ground/Leakage Current (Auto range, 50/60 Hz, True RMS,
Crest Factor < 3.5) Range Resolution Accuracy of
Reading
0.200 - 1.000 mA 0.001 mA ± 2.0% ± 0.05 mA
1.00 - 10.00 mA 0.01 mA ± 2.0% ± 0.03 mA
10.0 - 100.0 mA 0.1 mA ± 2.0% ± 0.3 mA
100 - 1000 mA 1 mA ± 2.0% ± 3 mA
0.20 - 35.00 A(5637) 0.01A ±
2.0% ± 0.03A
0.20 - 15.00 A(5600,5601) 0.01A ± 2.0% ± 0.03A
0.20 - 30.00 A(5600,5601) 0.01A ± 3.0% ± 0.03A
Accuracy of Resistance Calibration Plate: ±0.5%
Data Logging Capacity:116 records
Data Logging Interval: 1 to 255 seconds
Conductor Size: 35mm /1.38”(5637), 23mm /0.90”(5600,5601)
Jaw Opening: 38mm /1.49”(5637), 27mm /1.06”(5600,5601)
Battery Type: 9V IEC 6 LR61 (Alkaline) Low Battery
Indication:
Display Type: 4 digits 9999 counts LCD Range Selection:
Auto
Overload Indication: OL Power Consumption: 40mA
Battery Life: 3000 measurements Sampling Time: 0.5 seconds
Operating Temperature: 0 C to 50 C (14 F to 122 F)
Operating Humidity: Less than 85% RH
Storage Temperature: -20 C to 60 C (-4 F to 122 F) Storage
Humidity: Less than 75% RH
Dimension( 5637 ): 276mm (L) x 100mm(W) x
47mm(H),10.8" (L) x 3.9"(W) x 1.9"(H)
Dimension( 5600,5601 ): 257mm (L) x 100mm(W) x
47mm(H),10.1" (L) x 3.9"(W) x 1.9"(H)
Weight( 5637): 750g/1.65lbs
Weight( 5600,5601): 640g/1.41lbs
Accessories: Resistance Calibration Plate x 1 Battery 9V
(Installed) x 1
Users Manual x 1 Carrying Box x 1
|