Home Catalog Useful Links Enquiry Contact Us

AC+DC Power
(600V max., Auto-range and Manual)

Range

Resolution

Accuracy (of reading)

Overload Protection

400KW

0.1KW

±2.5%±5dgts

600VAC

1200KW

1KW

±2.5%±5dgts

600VAC


Temperature ℃
(K-type Thermal Couple, Auto-range and Manual), or ℉

Range

Resolution

Accuracy

Overload Protection

-50 - 400℃

0.1℃

±1.% ±2℃

600VAC

-400 - 1000℃

1℃

±1.% ±2℃

600VAC

-50 - 400℉

0.1℉

±1.% ±3℉

600VAC

-400 - 1000℉

1℉

±1.% ±3℉

600VAC


Resistance (Ω) and Continuity:
(open voltage 0.4V)

Range

Resolution

Accuracy

Beeping

OL Protection

40-400Ω

0.1Ω

±1.0% rdg±2dgts

< 40.0 Ω

AC 600V


General Specification

Conductor Size:

Cable Φ55mm. (approx.)

Bus Bar 65mm(D) x 24mm(W)

Battery Type:

9V

Display:

3 3/4 LCD with 40 seg. bargraph

Range Selection:

Auto and manual

Overload Indication:

left most digit blinks

Power Consumption:

12 mA (approx.)

Low battery Indication:

Sampling Time:

2 times/sec. (display) 20 times/sec. (bargraph)

Operating Temperature:

4°C to 50°C

Operating Humidity:

less than 85% relative

Altitude :

up to 2000M

Storage Temperature:

-20°C to 60°C

Storage Humidity:

less than 75% relative

Dimension:

271mm (L) x 112mm (W) x 46mm (H)

10.7" (L) x 4.4" (W) x 1.8" (H)

Weight:

647 g/22.8 oz (batteries included)

Accessories:

Carrying bag x 1

Users manual x 1

9V battery x 1, installed

Options:

Thermal couple adapter

K-type thermal couple

 

 PROVA 2009 AC/DC TRMS WATT CLAMP
1. AC+DC 400/1200KW, auto-range
2. DC 2500A, AC 2100A, and AC/DC 600V.
3. Φ55 mm diameter jaw.
4. One touch zero for DCA,DCW adjustment.
5. Auto-range for A, V, W, and temperature (℃ or 
 ℉)
6. Large 3 3/4 digits LCD
6. Fast bargraph display (20 times/sec.) for transient
 observation.
7. Continuity with buzzer.
8. Max/Min and Data Hold functions.
9. 600V overload protection for ohm measurement.
10. Easy single rotary switch for any function 
 selection.
 

Specifications


DC Current:

Range

Resolution

Accuracy (of rdg)

Overload Protection

400A

0.1A

±1.5%±3dgts

DC 3000A

0-2000A

1A

±1.5%±3dgts

DC 3000A

2000-2500A

1A

±2.0%±3dgts

DC 3000A


AC Current (True RMS, Crest Factor < 3):

Range

Resolution

Accuracy (of rdg)

Overload Protection

50/60 Hz

40 - 1KHz

400A

0.1A

±1.5%±5dgts

±2.0%±5dgts

AC 3000A

0-1000A

1A

±2.0%±5dgts

±2.5%±5dgts

AC 3000A

1000-2100A

1A

±2.5%±5dgts

±3.0%±5dgts

AC 3000A


Current Analog Output

Range

Output

Accuracy

Overload Protection

0 - 400A

1mV/A

±2.5% ±0.5A

600V AC

400 - 2100A

1mV/A

±2.5% ± 5A

600V AC


DC Voltage:
(Autorange & Manual, Overload Protection 800VAC for all range)

Range

Resolution

Accuracy(of rdg)

Input Impedance

400mV

0.1mV

±1.5%±3dgts

10MΩ

4V

0.001V

±1.5%±3dgts

5MΩ

40V

0.01V

±1.5%±3dgts

5MΩ

400V

0.1V

±1.5%±3dgts

5MΩ

600V

1V

±1.5%±3dgts

5MΩ


AC Voltage
( True RMS, Crest Factor < 3,Autorange & Manual, Overload Protection 800VAC for all range)

Range

Resolution

Accuracy (of reading)

Input Impedance

50/60 Hz

40 - 1KHz

400mV

0.1mV

--------(1)

--------(1)

--------(1)

4V

0.001

±1.5%±5dgts

±2.0%±5dgts

5MΩ

40V

0.01V

±1.5%±5dgts

±2.0%±5dgts

5MΩ

400V

0.1V

±1.5%±5dgts

±2.0%±5dgts

5MΩ

600V

1V

±1.5%±5dgts

±2.0%±5dgts

5MΩ

(1) 400mVAC is not designed to measured AC mV. So no accuracy is listed.

AC+DC Power
(250V max., Auto-range and Manual)

Range

Resolution

Accuracy (of reading)

Overload Protection

40KW

0.01KW

±2.5%±5dgts

600VAC

400KW

0.1KW

±2.5%±5dgts

600VAC