PROVA
15 AC/DC mA CUREENT PROBE |
|
Features
|
1. Accurate DC/AC current probe for current
measurement.
2. 1mDCA high resolution on 4A DC range.
3. 0.1mACA high resolution on 400mA AC range
3. One touch zero for DCA adjustment.
4. 23 mm diameter jaw.
|
|
Specifications(23°C±5°C)
|
| |
AC
Current:
|
Range
|
Output
|
Accuracy
|
|
DC
400mA (1)
|
DC
1mV/mA
|
----------------(1)
|
|
DC
4A
|
DC
100mV/A
|
±2.0%±3mA
|
|
DC
30A
|
DC
10mV/A
|
±2.0%±30mA
|
|
|
50/60Hz
|
40-100Hz
|
|
AC
400mA
|
AC
1mV/A
|
±2.0%±0.5mA
|
±2.5%±0.5mA
|
|
|
50/60Hz
|
40-400Hz
|
|
AC
4A(0-400mA)
|
AC
100mV/A
|
±2.5%±8mA
|
±3.0%±8mA
|
|
AC
4A(400mA-4A)
|
AC
100mV/A
|
±2.5%±3mA
|
±3.0%±6mA
|
|
AC
30A
|
AC
10mV/A
|
±2.0%±30mA
|
±2.5%±30mA
|
(1)
400mA
range is not designed for DC current measurement. The
accuracy is ±2.5%±1mA, and it is only used for
reference. In the DC400mA range, the output would show
0.4mV drifting (rdg, rdg+0.1, rdg+0.2, rdg+0.3, rdg+0.4,
rdg+03, rdg+0.2, rdg+0.1, rdg,...).
|
Range
|
Sensitivity
|
|
DCA
4A
|
0.1mV/1mA
DC
|
|
DCA
40A
|
0.1mV/10mA
DC
|
|
ACA
400mA
|
0.1mV/0.1mA
AC
|
|
ACA
4A
|
0.1mV/1mA
AC
|
|
ACA
40A
|
0.1mV/10mA
AC
|
|
General
Specification
| Conductor
Size: |
23mm
max. (approx.) |
| Battery
Type: |
two
1.5V SUM-3 AA |
| Range
Selection: |
manual |
| Power
Consumption: |
10
mA (approx.) |
| Low
battery Indication: |
 |
| Operating
Temperature: |
-10°C
to 50°C |
| Operating
Humidity: |
less
than 85% relative |
| Storage
Temperature: |
-20°C
to 60°C |
| Storage
Humidity: |
less
than 75% relative |
| Altitude: |
up
to 2000M |
| Dimension: |
183mm(L)x61.3mm(W)x35.6mm
(H) |
| 7.2"
(L) x 2.5" (W) x 1.4" (H) |
| Weight: |
190g
(battery included) |
| Accessories: |
Carrying
bag x 1 |
| Users
manual x 1 |
| Test
leads |
| 1.5V
battery x 2 |
|
|
|
|
|
|
|
|