LUTRON PH-207 Digital PH Meter with PE-03 sensor

* Microprocessor circuit assures high accuracy and provides special functions and features.
* Super large LCD display with contrast adjustment for best viewing angle.
* Dual function meter's display.
* Heavy duty & compact housing case.
* Records Maximum, Minimum and Average readings with RECALL.
* Data hold.
* Auto shut off saves battery life.
* Operates from OO6P DC 9V battery.
* RS 232 PC serial interface.
* Used the durable, long-lasting components, including a strong, light weight ABS-plastic housing case.
* Multi-measurement : PH, mV, Temperature.
* Temperature function for °C or °F be selected by push button on front panel easily.
* Show the PH & temperature values on the same LCD display at the same time.
* High input impedance avoid measuring error.
* Wide manual temperature compensation range from 0 °C to 100 °C , high accuracy.
* Auto temperature compensation range via. the external optional temp. probe.
* The values of "Manual temp. compensation" are reading from the LCD display directly, no errors & easy operation.
* With the optional temp. probe for automatic temp.
compensation of PH function or temp. measurement.
* The instrument build in mV(milli volt) measuring function, letting you make ion-selective, ORP, and other precise mV measurement.
* Wide applications: water conditioning, aquariums, beverage, fish hatcheries, food processing, photography, laboratory,paper industry, plating industry, quality control, school & college, water conditioning.

 

SPECIFICATIONS

2-1 General Specifications

Circuit

Custom one-chip of microprocessor LSI circuit.

Display

Dual function meter's display, 13 mm(0.5" Super large LCD display with contrast adjustment for best viewing angle.

Measurement

 

 

PH

0 to 14 PH

mV

0 to 1999 mV

Temperature

0 to 65 °C

32 to 150 °F

Input

Impedance

1012ohms.

Temperature

Compensation

For

PH Range

 

Manual

0 to 100 °F , adjusting by push button on front panel.

Automatic

With the optional TEMP. probe, 0 to 65 °F

Input

Impedance

1012ohms.

Temperature

Compensation

For

PH Range

 

Manual

0 to 100 °F , adjusting by push button on front panel.

Automatic

With the optional TEMP. probe, 0 to 65 °F .

Calibration

For

PH Range

Built in SLOPE(PH 4) & CAL.(PH 7 calibration VR ( multi-turns potentiometers ) on front panel, high reliability.

Data hold

To hold the reading values on display.

Memory

Recall

Records Maximum, Minimum and Average readings with RECALL.

Power off

Auto shut off saves battery life, or manual off by push button.

Data Output

RS 232 PC serial interface.

Over input

indication

Indication of "- - - -".

PH

Electrode

Any combination PH electrode with BNC connector/

Operating

Temperature

0 °C to 50 °C (32 °C  to 122 °C ).

Operating

Humidity

Max. 80% RH.

Sampling Time

Approx. 0.8 second.

Power Supply

006P DC 9V battery(Heavy duty type).

Power Current

Approx. DC 5.7 mA.

Weight

270 g/0.59 LB (included batteries)

Size ( meter )

180 x 72 x 32 mm(7.1 x 2.8 x1.3 inch).

Standard

Accessories

Instruction manual...........1 PC.

Optional

Accessories

Carrying case

pH electrode, PE-01, PE-11, PE-03.

ATC temp. probe, TP-07.

PH 4 buffer solution, PH-04.

PH 7 buffer solution, PH-07.

2-2 Electrical Specifications (23±5 °C )

Measurement

Range

Resolution

Accuracy

PH

0 to 14 PH

0.01 PH

±(0.03 PH+2d)

mV

0 to 1999 mV

1mv

±(0.5%+1d)

Temp.( °C )

0 to 65 °C

0.1 °C

1.2 °C

Temp.( °F )

32 to 150 °F

0.1  °F

2.2 °F

*PH accuracy are based on after calibration, meter only.

*For PH function, though display unit is 0.01 PH but the internal A/D circuit resolution is 0.02 PH.

*Spec. tested under the environment RF Field Strength less

than 3 V/M & frequency less than the 30 MHz only.

 
 
 