KYORITSU
8112 CLAMP ADAPTOR |
• AC CLAMP ADAPTOR
• Model 8112 clamp adaptor is designed to be an AC current/voltage conversion probe capable of measuring AC current from 0.1mA to 120A in conjunction with digital multimeters.
Simple to operate, the unit has range switch position at 200mA,2A and 20A. It also features safety design throughout with no exposed metal parts.
|
|
Range
|
Measuring
Ranges
|
Output
Voltage
|
Accuracy
|
Frequency
Response
|
|
200mA
|
AC
0~500mA
|
AC1V/A
(1000mA→1V)
|
|±1.5%rdg±0.2mA
|
50Hz~1kHz
|
|
AC
0~1000mA
|
|±3%rdg±0.4mA
|
40Hz~10kHz
|
|
2A
|
AC
0~20A
|
AC100mV/A
(20A→2V)
|
|±1%rdg±1mA
|
40Hz~1kHz
|
|
|±1.5%rdg±2mA
|
1k~10kHz
|
|
20A
|
AC
0~20A
|
AC10mV/A
(120A→1.2V)
|
|±1%rdg±0.01A
|
40Hz~1kHz
|
|
AC
20~60A
|
|±2.5%rdg
|
50Hz~10kHz
|
|
AC
60~120A
|
|±2.5%rdg
|
100Hz~10kHz
|
|
Conductor
Size
|
Ø8mm
max.
|
|
Frequency
Response
|
30Hz~100kHz
(-3dB)
|
|
Safety
Standard
|
IEC61010-1
CAT.II 100V Pollution Degree 2
|
|
Withstand
Voltage
|
500V
AC for 1 minute
|
|
Dimensions
|
153(L)
× 18(W) × 23(D)mm
|
|
Weight
|
100g
approx.
|
|
Accessories
|
9057(Carrying
Case)
Instruction Manual
|
|
|
|
|
|
|