KYORITSU 6011A

• Complies with IEC61557 
• Designed to IP 54 Rating 
• Live circuit and wiring connection check LED's 
• Triple ranges insulation tests at 250, 500 and 1000V 
• Triple range loop and PSC tests 15mA test current at 200Ω/2000Ω range(No RCD Trip) 
• Phase angle selection on RCD ranges 
• Polarity switch for continuity tests 
• Auto-null facility for continuity tests 
• DC test for DC sensitive RCDs 
• Earth probe for loop impedance testing on extraneous metalwork 
• Contact Voltage Reading 

Continuity Testing

Measuring Ranges

20/200/2000Ω (Autoranging)

Open Circuit Voltage

>6V

Short Circuit Current

>200mA DC

Accuracy

|±(1.5%rdg+3dgt)

Insulation Testing

Measuring Ranges

20/200MΩ(Autoranging)

Test Voltage

250V 500V 1000V DC

Output Voltage on
Open Circuit

250V+40%-0%
500V+30%-0%
1000V+20%-0%

Rated Current

> 1mA

Accuracy

|±(1.5%rdg+3dgt)

Loop Impedance Testing

Rated Voltage

230V AC +10%-15% [50Hz]

Voltage Measuring Range

100~250V AC [50Hz]

Impedance Ranges

20/200/2000Ω

Nominal Test Current

25A (20Ω range) 15mA (200Ω range) 15mA (2000Ω range)

Accuracy

20Ω range ±(3%rdg +4dgt)
200Ω range ±(3%rdg +4dgt)
2000Ω range ±(3%rdg +4dgt)

PSC Testing

Rated Voltage

230V AC +10%-15% [50Hz]

PSC Ranges

200A(15mA Test Current)
2000A(25A Test Current)
20kA(25A Test Current)

Accuracy

PSC accuracy derived from measured loop impedance specification and measured voltage specification

RCD Testing

Rated Voltage

230V AC +10%-15% [50Hz]

Trip Current Settings

RCD × 1/2 : 10,30,100,300,500,1000mA
RCD × 1 : 10,30,100,300,500,1000mA
RCD × 5 : 10,30,100,300mA (on × 5 ranges max current 1A)

Trip Current Duration

RCD × 1/2 × 1: 2000ms
RCD fast: 50ms

Accuracy

Trip current +10%-0% of test current at 230V
Trip time ±(1%rdg + 3dgt)

General

Safety Standard

IEC61010-1 CAT.III 300V Pollution Degree 2
IEC61557

Withstand Voltage

3700V AC for 1 minute

Power Source

LR6 (1.5V) × 8

Dimensions

130(L) × 183(W) × 100(D)mm

Weight

1100g approx.

Accessories

*KAPM10
(Molded plug test leads for loop and RCD testing at sockets)
7122(lead for insulation and continuity testing)
KSLP5(external earth probe)
Pouch for Test Leads
Shoulder Strap
Battery LR6 (1.5V) × 8
Instruction Manual

Optional Accessories

OMA DIEC (Distribution board or lighting circuit test leads for LOOP/PSC/RCD testing)

 












 