MODEL
|
3321A
|
3322A
|
3323A
|
|
Insulation
Resistance
|
|
DC
Test Voltage
|
250V/500V/1000V
|
125V/250V/500V
|
25V/50V/100V
|
|
Measuring
Range
|
50MΩ/100MΩ/2000MΩ
|
20MΩ/50MΩ/100MΩ
|
10MΩ/10MΩ/20MΩ
|
|
Mid-Scale
Value
|
1MΩ/2MΩ/50MΩ
|
0.5MΩ/1MΩ/2MΩ
|
0.2MΩ/0.2MΩ/0.5MΩ
|
|
First
Effective
Measuring Range
Accuracy
|
0.05~20MΩ(250V)
0.1~50MΩ(500V)
2~1000MΩ(1000V)
|
0.02~10MΩ(125V)
0.05~20MΩ(250V)
0.1~50MΩ(500V)
|
0.01~5MΩ(25V)
0.01~5MΩ(50V)
0.02~10MΩ(100V)
|
|
|±5%
of Indicated Value
|
|
Second
Effective
Measuring Range
Accuracy
|
20~50MΩ(250V)
50~100MΩ(500V)
1000~2000MΩ(1000V)
|
10~20MΩ(125V)
20~50MΩ(250V)
50~100MΩ(500V)
|
5~10MΩ(25V)
5~10MΩ(50V)
10~20MΩ(100V)
|
|
|±10%
of Indicated Value
|
|
AC
Voltage
|
600V
|
|
Accuracy
|
|±3%
of Full Scale Value
|
|
Safety
Standard
|
|
IEC/EN 61010-1
|
CAT.III 600V,CAT.II 1000V
|
|
|
Withstand
Voltage
|
5550V
AC for 1 minute
|
|
Power
Source
|
R6P(AA)(1.5V)
× 6
|
|
Dimensions
|
105(L)
× 158(W) × 70(D)mm
|
|
Weight
|
520g
approx.
|
|
Accessories
|
7103(Test
Lead with Remote Control Switch)
Pouch for Test Leads
Shoulder Strap
7081(Guard
Connection Lead): 3321A only
8017(Extension
Prod)
R6P(AA) × 6
Instruction Manual
|
|
Optional
|
7115(Extension
Probe)
8016(Pickel
Type Prod)
9089(Carrying
Case)
|