KYORITSU 3132A
• Dust and drip proof construction. (designed to IEC60529 IP54) 
• Designed to meet IEC61010-1 and IEC61557 safety standard. 
• 1mA rated test current at the minimum resistance. 
• 200mA measuring current on continuity testing. 
• Automatic discharge of circuit capacitance.
(Any charge stored in the circuit under test will be automatically discharged after testing.) 
• Live circuit warning buzzer and neon lamp. 
• Small and lightweight. Shock resistant new case material. 
• AC voltmeter with linear, easy-to-read scale. 
• Operates on AA, R6P×6 dry batteries.



Insulation Resistance

Test Voltage

250V/500V/1000V

Measuring Ranges
(Mid-scale Value)

100MΩ/200MΩ/400MΩ
(1MΩ) (2MΩ) (4MΩ)

Output Voltage
on open circuit

Rated test voltage+20%, -0%

Nominal Current

1mA DC min.

Output Short
Circuit Current

1~2mA DC

Accuracy

0.1~10MΩ/0.2~20MΩ/0.4~40MΩ
(Accuracy Guaranteed Ranges) ±5% of indicated value

Continuity

Measuring Ranges
(Mid-scale Value)

3Ω/500Ω
(1.5Ω)/(20Ω)

Output Voltage
on open circuit

4.1V DC approx.

Measuring Current

210mA DC min.

Accuracy

|±1.5% of scale length

AC Voltage

AC Voltage

0~600V AC

Accuracy

|±5% of scale length

General

Safety Standard

IEC61010-1 CAT.III 600V Pollution Degree 2
IEC61010-2-031
IEC61557-1/2/4

IP Rating

IEC60529-IP54

EMC Standard

IEC61326-1

Withstand Voltage

3700V AC for 1 minute

Power Source

R6P(AA)(1.5V) × 6

Dimensions

106(L) × 160(W) × 72(D)mm

Weight

560g approx.

Accessories

7122(Test leads) Pouch for test leads
8923(F500mA/600V fuse) × 2
R6P(AA) × 6
Shoulder Strap
Instruction Manual












 