KYORITSU 3111V

Compact, lightweight and portable Insulation/Continuity Tester



 

KYORITSU 3111V

Test Voltage

250V/500V/1000V

Measuring Ranges
(Mid-scale Value)

0~100MΩ/

0~200MΩ/

0~400MΩ

(1MΩ)

(2MΩ)

(4MΩ)

Output Voltage
on open circuit

Rated test voltage ±10%

Rated Current

0.8mA DC approx.

Output Short
Circuit Current

2mA DC approx.

Accuracy Guaranteed
Ranges

0.05~10MΩ/0.1~20MΩ/0.2~40MΩ

Accuracy

|±5% of indicated value

Continuity Test

Measuring Ranges
(Mid-scale Value)

50Ω
(20Ω)

Output Voltage
on open circuit

0.6V DC approx.

Output Short
Circuit Current

300mA approx.

Accuracy

|±3% of scale length

General

Withstand Voltage

2200V AC for 1 minute

Power Source

R6P(AA)(1.5V) × 8

Dimensions

143(L) × 93(W) × 63(D)mm

Weight

500g approx.

Accessories

7025(Test leads)
fuse 250V/1A
9038(Carrying Case)
R6P(AA) × 8
Instruction Manual

 












 