"Excellent & Friendly Service. Got my item within 3 days! Ordered Kyoritsu 3125 on Webnesday and requested them to send us the goods by Saturday. I received it through CITY-LINK EXPRESS on Friday! Will buy again!" -RCE CONSTRUCTION SDN BHD
"My third deal with them. Price acceptable. Service Excellent. They have helped us to source several products that make it possible for us to fulfill our orders before deadline! Beginning I was a bit worry but they made it! My Customer-Telekom are happy with all the products! Will buy again! - As-per
Measurement of RCD trip time
Conducting testing of rated residual non-operating currents at × 1/2 Range, measuring RCD trip time at × 1 and × 5 Ranges.
•
Measurement of trip out current
Measuring trip out current by varying current automatically.
•
Remote Test
Enabling a user to hold the Test Leads with his both hands by locking the Test Button. Measurement will automatically start when the main voltage is detected.
•
Voltage Measurement
Carrying out a constant measurement of voltage in the stand-by mode at each Range.
•
Auto-detection of Contact voltage
Detecting the voltage to earth of Earth electrodes or Protective conductors during RCD test - when applying test currents - at measurement using EARTH in order to prevent electrical shocks caused by the damaged earth. Measurement will be ceased at AC50V or more.
•
Dust- and Water-proof
Dust- and Water-proof construction (designed to IEC60529 IP54).
•
Backlight
Facilitating working at dimly illuminated locations.
Measurement of RCD trip time - Measurement of trip out current
Range
×5
×1
×1/2
AUTO RAMP (mA)
Rated Voltage
100V±10%
200V+32%/-10%
400V±10%
(50/60Hz)
Test current
15/30/50/100mA
15/30/50/100/200/500mA
15/30/50/100/200/500mA
Measuring range
Testing time
200ms
Testing time
2000ms
Testing time
2000ms
40%~110% of lΔn
(goes up by 5%)
Testing time
300ms × 15steps
-20ºC~60ºC, relative humidity 85% (no condensation)
Withstand Voltage
AC3700V / 1 min. (between electrical circuit and enclosure)
Insulation resistance
50MΩ or more / 1000V (between electrical circuit and enclosure)
Sleep Function
(1)
Automatically enters Sleep mode in 3 minutes after the last switch operation (current consumption 75µA). This function doesn't work at voltage measurements. To exit from the Sleep mode, set the Function switch to OFF position once, and re-set it to the Range at which a measurement to be conducted.
(2)
Backlight turns off in 1 minute after it lights up.
Power Source
DC 12V / Size AA battery R6P (SUM-3) × 8 pcs.
Dimension
186(L)×167(W)×89(D)mm
Weight
Approx. 965g (including batteries)
Possible number of Measurements
1200 times or more
(measure every 30 seconds at ×1/2 Range, lΔn=100mA)
RCD-06 (japan)
•
Custom microprocessor controlled for highest accuracy and reliability.
•
3 LEDs for checking correct wiring status.
•
0 and 180 degree phase angle switch permits quick tests and consistent readings.
•
Digital read-out of tripping time.
•
Constant current source circuitry ensures that a fluctuating mains voltage does not affect the accuracy of readings.
•
Large custom digital display readout.
•
Visual indication of reversed phase and neutral wiring at socket.
•
Designed to IP54 Rating.
•
Complies with IEC61557
•
Test of a large kind of RCD's:
Standard, Selective, AC and A (DC sensitive breakers)
•
Custom microprocessor controlled for highest accuracy and reliability.
•
3 LEDs for checking correct wiring status.
•
0 and 180 degree phase angle switch permits quick tests and consistent readings.
•
Digital read-out of tripping time.
•
Constant current source circuitry ensures that a fluctuating mains voltage does not affect the accuracy of readings.
•
Large custom digital display readout.
•
Visual indication of reversed phase and neutral wiring at socket.
•
Designed to IP54 Rating.
•
Complies with IEC61557
•
Test of a large kind of RCD's:
Standard, Selective, AC and A
(DC sensitive breakers)
|Molded plug test leads
|Pouch for test leads
|Shoulder Strap
|Instruction Manual
Optional
|7121(Distribution board test leads)
RCD-02 (japan)
•
Accurate digital readout of tripping time.
•
Two neon lamps give quick check for correct wiring.
•
Compact, lightweight and simple to operate.
•
Zero cross circuitry permits testing at 0 and 180 degree portion of sine wave. At these two tests minimum (best) and maximum (worst) trip times will be displayed.
•
Accurate digital readout of tripping time.
•
Two neon lamps give quick check for correct wiring.
•
Compact, lightweight and simple to operate.
•
Zero cross circuitry permits testing at 0 and 180 degree portion of sine wave. At these two tests minimum (best) and maximum (worst) trip times will be displayed.
Rated Tripping Current
5/10/30/100/300/500mA
Fault Condition Settings
× 1/2, × 1, Fast (250mA)
Trip Current Duration
2000ms, 40ms (Fast Trip)
Lowest Resolution
1ms
Trip Time Accuracy
|±2%rdg±3dgt
Operating Voltage
220/230/240V 50Hz/60Hz
Withstand Voltage
2200V AC for 1 minute
Dimensions
140(L) × 90(W) × 20(D)mm
Weight
350g approx.
Accessories
7019(Test Leads)
Carrying Case
Instruction Manual
KKInstruments V2.0 - We help your to measure with more confidence.
For customer service: Johor Office: Suite 3, 9th floor, Wisma Singlong, 9 Jln Zabedah, B.P 83000,
Johor,MY.
Tel(Johor) : +607- 4352540, 4355540
Fax: +607-4347299
Email:
This email address is being protected from spam bots, you need Javascript enabled to view it