GREENLEE DML-430 DIGITAL LOGGING METER 

• True RMS, autoranging, 3-5/6-digit, 5000-count display for greater accuracy.

• Selectable sampling intervals between 0.05 seconds – 480 seconds, 8-month max

(DML-430) logging period.

• 0.05 second memory rate to capture fast transients.

• Backlit display for easy viewing.

• Frequency, temperature and capacitance measurements and diode and continuity

tests standard.

• RS-232 capable, may be connected to a PC for extended measurement capability

with optional interface DMSC-8L.

• Accessories included: (1) 9V battery, bead temperature probe (400°F/ 204°C max.),

test leads, protective boot, carrying case.

CAT. NO. UPC NO. DESCRIPTION

DML-430 07553 Digital Logging Meter (43,000 data points)

DML-430-C* 07620* Digital Logging Meter (43,000 data points)

DML-54 07552 Digital Logging Meter (5,400 data points)

DML-54-C* 07619* Digital Logging Meter (5,400 data points)

TC-20 07535 Carry Case (included)

SPECIFICATIONS

Voltage Measurement 50.00, 500.0mV; 5.000, 50.00, 500.0, 1000V

Amperage Measurement 500.0, 5000μA; 50.00, 500.0mA; 5.000, 10.00A

Resistance 50.00, 500.0Ω 5.000, 50.00, 500.0kΩ 5.000, 50.00M

Capacitance 50.00, 500.0nF; 5.000, 50.00, 500.0, 9999μF

Frequency 10Hz-125kHz

Temperature K type, -58°F to 1832°F (-50°C to 1000°C)

Measurement Category Cat IV, 600V; Cat III, 1000V