Fluke
330 Series Clamp Meters |
- Three year warranty
- Small body and jaws fit perfectly in your hand and into
tight places
- Handy 'Display Hold' button keeps measurements on the
display
- Meter controls are positioned so current measurements can
be done with one hand (index finger on clamp opening lever
and thumb on rotary switch)
- Large, backlit display (on most models) is easy-to-see
- In-rush current function (on most models) for measuring
starting current for motors, lighting, etc.
- Auto shut-off maximizes battery life so the meter works
when you need it
- Improved low current measurement accuracy from new
microprocessor technology
- Five different models to meet your exact needs
|
| Fluke 330 Series Clamp
Meters |
 |
| Specifications |
| Voltage DC |
| Range: |
0 - 600.0 V |
| Accuracy: |
1% ± 5 counts |
|
| Voltage AC |
| Fluke 333/334 |
|
| Range: |
0 - 600.0 V |
| Accuracy: |
1% ± 5 counts
(50/60 Hz) |
| AC Response: |
Averaging |
| Fluke 335 |
|
|
|
| Range: |
0 - 600.0 V |
| Accuracy: |
1% ± 5 counts
(50/60 Hz) |
| AC Response: |
True-rms |
|
|
| Fluke 336/337 |
|
| Range: |
0 - 600.0 V |
| Accuracy: |
1% ± 5 counts
(20-100 Hz), 6% ± 5 counts (100-400 Hz) |
| AC Response: |
True-rms |
|
| Current DC |
| Fluke 336 |
|
| Range: |
0 - 600.0 A |
| Accuracy: |
2% ± 3 counts |
|
|
| Fluke 337 |
|
| Range: |
0 - 999.9 A |
| Accuracy: |
2% ± 3 counts |
|
| Current AC |
| Fluke 333/334 |
|
| Range: |
0 - 400.0 A |
| Accuracy: |
2% ± 5 counts
(50/60 Hz) |
| AC Response: |
Averaging |
|
|
| Fluke 335 |
|
| Range: |
0 - 600.0 A |
| Accuracy: |
2% ± 5 counts
(50/60 Hz) |
| Crest
Factor(50/60 Hz): |
2.4 @ 500A, 2.0 @
600A, add 2% for CF>2 |
| AC Response: |
True-rms |
|
|
| Fluke 336 |
|
| Range: |
0 - 600.0 A |
| Accuracy: |
2% ± 5 counts
(10-100 Hz), 6% ± 5 counts (100 - 400 Hz) |
| Crest
Factor(50/60 Hz): |
3 @ 500A, 2.5 @
600A, add 2% for CF>2 |
| AC Response: |
True-rms |
|
|
| Fluke 337 |
|
| Range: |
0 - 999.9 A |
| Accuracy: |
2% ± 5 counts
(10-100 Hz), 6% ± 5 counts (100 - 400 Hz) |
| Crest
Factor(50/60 Hz): |
3 @ 500A, 2.5 @
600A, 1.42@1000 A, add 2% for CF>2 |
| AC Response: |
True-rms |
|
| Resistance |
| Fluke 333 |
|
| Range: |
0 - 600.0 Ω |
| Accuracy: |
1.5% ± 5 counts |
|
|
| Fluke
334/335/336/337 |
|
| Range: |
0 - 600.0 Ω,
6001 - 6000 Ω |
| Accuracy: |
1.5% ± 5 counts |
|
| Frequency |
| Fluke 337 |
|
| Range: |
5 - 400Hz |
| Accuracy: |
0.5% ± 5 counts |
| Trigger Level: |
10-100 Hz >= 5A,
5-10 Hz, 100-400 Hz >=10A |
|
| Inrush Current |
| Fluke
334/335/336/337 |
|
| Integration Time: |
100 ms |
|
| Continuity |
|
| MIN/MAX |
|
| Environmental
Specifications |
| Operating
Temperature |
|
-10 °C to +50 °C,
-14 °F to 122 °F |
|
| Storage
Temperature |
|
-40ºC to +60ºC,
-22 °F to 140 °F |
|
| Operating
Altitude |
|
2,500 meters max,
6,500 ft max |
|
| Temperature
De-rating |
|
Add 0.1 x specified
accuracy for each ºC above 28ºC or below
18ºC (above 82.4°F or below 64.4°F) |
|
| Safety
Specifications |
| Safety Rating |
|
IEC 1010-2-032,
600V CAT III |
|
| Mechanical
& General Specifications |
| Size |
| Fluke 333/334/335 |
|
|
240mm x 80mm x 40mm
(9.375" x 3.125" x 1.625") |
|
- |
| Fluke 336/337 |
|
|
250mm x 80mm x 40mm
(9.875" x 3.125" x 1.625") |
|
| Weight |
|
| Warranty |
|
| Battery Life |
|
Alkaline
approximately 150 hours continuous |
|
Automatic low
battery indicator |
|
| Backlight |
|
| Display Hold |
|
|
|
|
|
|
|
|