Fluke
187/189 Digital/Analog Multimeter |
- Extremely fast readings
- 50,000 counts display
- 0.025% basic DC accuracy
- True RMS AC + DC measurements
- 100 kHz AC bandwidth for voltage and current
- Ergonomic high-impact overmolded case
- Dual display with bargraph and two-level backlight
- Min/max/average with real time clock and 250 µs Fast
Min-Max
- Frequency, capacitance, duty cycle & pulse width
measurements
- Resistance, conductance, continuity and diode measurements
- Temperature and dBV/dBm with selectable reference
- PC interface for data exchange and closed case calibration
- Battery and fuse access without breaking calibration seal
- EN 61010-1 (IEC 1010-1) CAT III 1000V /CAT IV 600V
- Lifetime warranty
- Internal memory allows stand-alone logging of up to 1000
measurements (189 only)
- Readings memory for up to 100 readings (189 only)
|
|
 |
| Specifications |
| Voltage
DC |
| Accuracy* |
±
(0.025%+5) |
| Max.
Resolution |
1 µV |
| Maximum |
1000 V |
|
| Voltage
AC |
| Accuracy* |
±
(0.4%+40) |
| Max.
Resolution |
1 µV |
| Maximum |
1000 V |
|
| Current
DC |
| Accuracy* |
±
(0.15%+2) |
| Max.
Resolution |
0.01 µA |
| Maximum |
10 A |
|
| Current
AC |
| Accuracy* |
±
(0.75%+5) |
| Max.
Resolution |
0.01 µA |
| Maximum |
10 A |
|
| Resistance |
| Accuracy* |
±
(0.05%+2) |
| Max.
Resolution |
0.01
Ω |
| Maximum |
500 MΩ |
|
| Capacitance |
| Accuracy* |
±
(1.0%+5) |
| Max.
Resolution |
1 pF |
| Maximum |
50,000 µF |
|
| Frequency |
| Accuracy* |
±
(0.005%+1) |
| Max.
Resolution |
0.01 Hz |
| Maximum |
1 MHz |
|
| Temperature |
| Accuracy* |
±
(1.0%+1°C) |
| Max.
Resolution |
0.1°C |
| Range |
-200°C
to 1350°C |
|
| Conductance |
| Accuracy* |
±
(1%+10) |
| Max.
Resolution |
0.01 nS |
| Maximum |
500 nS |
|
| dBm
and dBV |
| Accuracy* |
± 0.1 dB |
| Max.
Resolution |
0.01 dB |
| Range |
-52 to 60
dB |
|
| Note |
| * |
Accuracies
are best accuracies for each
function |
|
| Environmental
Specifications |
| Operating
Temperature |
|
| Storage
Temperature |
|
| Humidity
(Without Condensation) |
|
0% to 90%
(0 °C - 35 °C) |
|
0% to 70%
(35 °C - 55 °C) |
|
| Safety
Specifications |
| Overvoltage
category |
|
EN
61010-1 to 1000 V CAT III. |
|
EN
61010-1 to 600 V CAT IV. |
|
| Agency
Approvals |
|
CSA, UL,
TÜV, VDE Pending |
|
| Mechanical
& General Specifications |
| Size |
|
| Weight |
|
| Warranty |
|
| Battery
Life |
| Alkaline: |
~72 hours
typical, without backlight |
|
|
|
 |
 |
|
|
|
|
|
|