Fluke 1520 MegOhmMeter
  • Large, backlit LCD with analog bar graph and digital display
  • Three output voltages for insulation resistance testing: 250V, 500V, 1000V
  • Insulation resistance testing up to 4000 M Ohms; switches automatically to voltage measurement when voltage is greater than 30V ac or 30V dc.
  • ac/dc voltage measurement up to 600V
  • Lo-Ohms function for testing connections
  • Last reading memory display
  • 4 C-cell batteries for up to 5,000 tests per EN61557-2, with battery-life indicator and auto shut-off.
  • Autodischarge of capacitive voltage charges
  • Rugged, splash-proof case with impact absorbing holster.
 
Fluke 1520 MegOhmMeter
Specifications
Auto ranges
Accuracy: To 100 MΩ
Resolution: 0.001MΩ to 10 MΩ
Range: 4.000 MΩ, 40.00 MΩ, 400.0 MΩ, 4000 MΩ
Test voltages
Accuracy: +20%, -0%
Range: 250V, 500V, 1000V
Max measurement current
1 mA
Audible/visible voltage warning
>= 30V ac or dc
Lo-Ohms Resistance
Accuracy: 2% + 2 counts
Resolution: 0.01Ω
Range: 0 to 40.00Ω
Lo-Ohms Analog bar graph
0 to 100Ω
Lo-Ohms Audible/visible voltage warning
>= 30V ac or dc
Resistance
Accuracy: 2% + 2 counts
Resolution:
Range: 4 kΩ
Analog bar graph
0 to 10 kΩ
Voltage
Range: 0 to 600V ac (50/60 Hz), 0 to 600V dc
Accuracy: 2% + 2 counts
Resolution: 1V

Environmental Specifications
Operating Temperature
-10°C to +50°C ( +14°F to +122°F)
Storage Temperature
-40°C to +70°C (-40°F to +158°F)
Humidity (Without Condensation)
75% RH (40°C) or (104°F)
Dust/water resistance
IP42 per IEC 529
Operating Altitude
2,500 m max (8125 ft max)

Safety Specifications
Electrical Safety
Meets IEC 1010-1 and EN 61557
Protection Class
Pollution degree II
Overvoltage category
IEC 1010-1 CAT III 600V
Agency Approvals
UL, CSA, TÜV (pending)

Mechanical & General Specifications
Battery check function
Indicates remaining percent of charge
Size
241mm x 108mm x 72 mm (9.5" x 4.25" x 2")
Weight
1.1 kg (2.5 lbs)
Batteries
4 C size 1.5V alkaline
Warranty
3 years