DAGATRON AFG 100
Not for sale in Europe 

◎ 0.01㎐ - 12.5M㎐ arbitrary generator with DDS (Direct Digital Synthesis) 
◎ Max. sample rate 33MS/S 
◎ Arbitrary, sine, square wave, triangle, ramp signal 
◎ Accuracy of frequency setting - ±0.01% ±0.002㎐ 
◎ Internal sweep (sweep time 10ms~60s)-sweep mode (linear, logarithmic - discrete) 
◎ Amplitude Modulation - internal (depth, frequency), external 
◎ Synchronization output - square wave signal (COMS / TTL level) 
◎ DCV offset adjusted within a wide range 
◎ Auto - calibration 
◎ Protection of the signal output - if an external voltage V>± 15V, switches itself off automatically 
◎ LCD adjustment (bright / contrast) 
◎ Pre-setting(memory)- store / recall 
◎ RS-232C interface 
◎ Radio interference suppression - EN 55011 Class B 
◎ Safety class - I according to EN 61010 Part 1 
 
 

Frequency range

0.01㎐... 12.5 M㎐ for sinusoidal and square wave signals
0.01㎐... 100 ㎑ for triangular and ramp signals

Frequency setting

5 digits or 0.001㎐

Accuracy of the frequency setting (at nominal temperature)

±0.01% ±0.0002㎐

Duration of the auto-calibration of the frequency

abt. 0.8s for f>100㎐,abt. 0.8...30s for f<100㎐

Temperature coefficient of the frequency

±100ppm in operating temperature range

Ouput impedance

50Ω ± 1.5%, unsymmetrical

Ouput voltage Uss

10㎷... 10 V / 50Ω

Ouput voltage setting

3 digits

Accuracy of output voltage at f =1㎑

±(2% + 20㎷)

Additional frequency error of output voltage

±1dB in the range 10㎐...1M㎐,±3 dB 0.01㎐...10M㎐

Temperature coefficient of output voltage

<±5 × 10-3 / K

Direct voltage offset of signal(Voltset)

±2.5V in 10㎷ steps

Accuracy of offset voltage setting

±(1% + 20㎷)

Output signal

sinusoidal, square wave, triangular, ramp(up, down) arbitrary

Distortion factor of sinusoidal signal

<0.5% in the range 10㎐... 100㎑

Nonlinear distortion factor of the sine signal

<1% for 20㎐... 20㎑, <5% for 100㎑... 10M㎐

Rise time of square wave signal

<25ns

Overshoot of square wave signal

<0.5% + 30㎷

Non-linearity of triangular signa
l(5%... 95%)

<1%

Horizontal resolution(length of signals)

8192 points

Vertical resolution of level

1024 points (10 Bit)

Sample period

30ns × 2N-1, N=1...32

SWEEP function

Frequency change for the SWEEP function

0.01㎐... 12.5M㎐ (100㎑ for triangular and ramp signals)

Sweep type

linear, logarithmic - discrete

Direction of frequency change

rising, falling

Period of repetition for the SWEEP function

10ms... 60s

Amplitude modulation

Source of modulation signal

internal, external

Frequency range of external modulation input

0 ㎐... 20 ㎑

Amplitude of external signals (Vpp)

2V for AM modulation depth m = 100%

Input impedance of external AM input

100 ㏀

\Frequency range of internal modulation oscillator

from approx. 100㎐ to approx. 10㎑, discrete frequency values

Depth of amplitude modulation

0 to 100%, 1% steps for internal generator of AM

Square wave synchronization output

Output voltage Vpp

5V±10% CMOS

Duty cycle of output signal

approx. 1:1 for periodical signals pulse "Start" with a width of approx. 5μs at the sweep function

▣ General Data

Nominal temperature

+ 23 °C ± 2 °C

Operating temperature

+ 5 °C ... + 40 °C

Relative humidity

20 to 80%

Atmospheric pressure

70 to 106 kPa

Operating position

horizontal or inclined by ±15 °

Operating voltage

alternating voltage 230V /` 115V(+10%,-15%), 47-63 ㎐

Power consumption

27VA (max. 27W)

Safety class

l according to EN 61010 -1

Radio interference suppression

EN 55011 Class B

Dimensions (W × H× D)
Dimensions of packing

225 mm × 85 mm × 200 mm
315 mm × 115 mm × 270 mm

Weight
Weight incl. packing and accessories

approx. 2.5 kg
approx. 3.5 kg

▣ Accessories supplied with the package

mains cable, coaxial cable, operating instruction, spare fuses, diskette.

▣ System interfaces

The AFG 100 can be fully controlled and read out via the serial interfaces RS-232C.
The data transfer is based on the ASCII character set.